Omnes Categoriae

Servo Motor Gearbox Selection Guide: Flange Compatibility & Integration

Aug 24, 2026

Brevis Responsum: Matching a servo motor to a gearbox requires verifying four interface dimensions: bolt hole pitch circle diameter, hole diameter and distribution, shaft extension diameter, and keyway spec. Wuma Drive's WMRV, WR, WK, WF, WS, and WKM series all include a dedicated Input Square Flange Dimension Comparison Table in the product catalog — download it at wumadrive.com/download to confirm compatibility before ordering.


1. The Integration Problem: Why Servo-to-Gearbox Matching Fails

In industrial automation, servo motors and gearboxes must be mechanically mated — yet they come from different standards worlds. Most gearbox manuals only document IEC standard flanges. Servo motors, by contrast, are offered by dozens of brands each with proprietary square flange dimensions — bolt hole pitch circle, hole diameter, shaft extension, and keyway — that differ by brand and frame size.

The result: engineers must manually cross-reference motor dimension drawings against gearbox input specs for every new project. This is slow, error-prone, and a frequent cause of costly assembly rework.

The fix is structural, not workaround-based: a dimension lookup table that maps motor brand and frame size directly to verified gearbox input dimensions.


2. What Dimensions Actually Matter for Flange Compatibility

When evaluating servo motor–gearbox compatibility, four dimensions determine whether the interface will fit and transmit torque reliably:

Bolt Hole PCD

Pitch circle diameter of the mounting bolt pattern. Mismatch here prevents physical assembly.

Hole Diameter & Distribution

Number and diameter of bolt holes. Even if PCD matches, hole count or size discrepancy blocks assembly.

Shaft Extension Diameter

Motor output shaft OD must match the gearbox input bore. Tolerance matters — H7/k6 fits are standard for precision applications.

Keyway Specification

Width, depth, and length of keyway. A mismatched keyway allows shaft-to-bore contact but fails under load — the most common hidden assembly defect.


3. Input Square Flange Dimension Comparison Table

Wuma Drive has added a comprehensive Input Square Flange Dimension Comparison Table to the product catalogs for all six gearbox series: WMRV (worm), WR (helical), WK (helical-bevel), WF (parallel shaft), WS (helical-worm), and WKM (hypoid) .

Each table entry maps a specific gearbox model to the verified input interface dimensions for mainstream servo motor brands — covering bolt hole PCD, hole diameter and count, shaft extension OD, and keyway spec. No manual cross-referencing against motor drawings is required.

Download the Full Dimension Tables

Tabulae comparationis dimensionum totalium flangii quadrati ad omnes sex series in catalogo officiali productorum Wuma Drive inclusae sunt. Gratis ad download disponibiles — nullum registratio requiritur.

Download Catalogi Productorum →

4. Selectio Serierum Reductorium per Applicationem

Electio seriei aptissimae pro applicatione tua servo-motoris ex torque output, directione axis, tolerantia soni, et limitibus spatii pendet. Tabula infra est brevis adiutorium ad emptionem:

SERIES Typus Directio axis Typicam Applicationem
WMRV Rota vermicularis Angulus rectus Conveyorae, agitatores, lineae impachandae
WR Helical In linea Impulsus conveyorarum alti velocitatis, ventilatores
WK Helical-bevel Angulus rectus Mixeria gravis officinae, impulsus machinarum levandarum, fractoria
WF Axis parallelus helicalis In linea (offset) Tabulae rotatoriae, convectores cinguli, machinae elevatrices
WS Vermis Helicalis Angulus rectus Impulsiones angulares compactae, agitatores leves
WKM Hypoid Angulus rectus Impulsiones servo ad altam efficaciam, vehicula automatica directa (AGV), automatizatio praecisa

Pro quaque serie, catalogus productorum tabulam comparationis dimensionum flangii quadrati input includit. Catalogum adhibere ut omnes datos dimensionum pro serie quaesita accedas.


5. Index emptionis: Antequam ordinare incipias

Use this checklist to validate servo motor–gearbox compatibility before placing an order:

1. Confirm motor flange type

Square or round? Record the frame size and brand.

2. Pull bolt hole PCD and hole count

Source from the motor datasheet or nameplate.

3. Check shaft extension OD and keyway spec

Record width × depth × length. Keyway mismatch is the most common hidden defect.

4. Cross-reference the Input Square Flange Dimension Table

Find your gearbox series and model row in the Catalogus—verify all four dimensions match.

5. Confirmare requisita output

Torque nominale, raportus velocitatis, et orientatio montagii (horizontalis / verticalis / muris-montatus).

6. Verificare gradum protectionis IP

Necessarium si ambientem installationis est humidus, pulvisosus, aut subiectus lavationi.

Si quaelibet dimensio extra normas catalogi cadit, contacterite aequipe ingeniaria Wuma Drive pro adaptatore input ad mensuram — supportamus interfacies motorum non-standardes in omnibus seriebus productorum.


Quaestiones Frequentes

Quomodo servo-motorem ad reductorem apto per typum flangae?

Identificare PCD foraminum bulonum flangae quadratae motoris, diametrum foraminum, diametrum exterius axis, et clavulam. Comparare haec ad Tabulam Comparationis Dimensionum Flangae Quadratae Input in Catalogo Wuma Drive . Nulla comparatio manu facta diagrammatum necessaria est.

Quae series Wuma Drive supportant input servo-motorum flangae quadratae?

Omnes sex series — WMRV, WR, WK, WF, WS, et WKM — suadent quadratum flangium motoris input cum tabulis dimensionum verificatis in officiali catalogo productorum.

Cur specificatio clavicularis est communissima occulta incompatibilitas?

Axis et foramen fortasse congruunt physice, sed latitudo aut profunditas clavicularis 0.1 mm abnormis causat fretting sub onere cyclico. Semper verificare specificationem clavicularis — latitudinem, profunditatem, et longitudinem — non solum diametrum externam axis.

Ubi catalogum productorum Wuma Drive downloadare possum?

Catalogus plenus, includens omnes Tabulas Comparationis Dimensionum Flangii Quadrati Input, gratis adhibetur apud wumadrive.com/download .

Potestne Wuma Drive tractare interfaces motorum non-standard?

Ita. Pro interfacebus extra normam catalogi, nostrum turma ingeniorum solutiones adaptatas pro input adapteribus praebet. Nos contace ut viabilitas confirmetur antequam ordinatur.


Paratus es ad specificandum tuum gearbox motus servo? Downloada tabulas dimensionum aut loquere cum nostris ingenioribus.

Catalogum recēde → Contace Nostros Ingeniores →

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000